Identification of Limiting Case Between DBA and SBDBA (CL Break Area Sensitivity): A New Model for the Boron Injection System

Authors

  • R. Gonzalez
  • A. Petruzzi
  • F. D’Auria
  • O. Mazzantini

DOI:

https://doi.org/10.37798/2013621-4220

Abstract

Atucha-2 is a Siemens-designed PHWR reactor under construction in the Republic of Argentina. Its geometrical complexity and (e.g., oblique Control Rods, Positive Void coefficient) required a developed and validated complex three dimensional (3D) neutron kinetics (NK) coupled thermal hydraulic (TH) model. Reactor shut-down is obtained by oblique CRs and, during accidental conditions, by an emergency shut-down system (JDJ) injecting a highly concentrated boron solution (boron clouds) in the moderator tank, the boron clouds reconstruction is obtained using a CFD (CFX) code calculation. A complete LBLOCA calculation implies the application of the RELAP5-3D© system code. Within the framework of the third Agreement “NA-SA – University of Pisa” a new RELAP5-3D control system for the boron injection system was developed and implemented in the validated coupled RELAP5-3D/NESTLE model of the Atucha 2 NPP. The aim of this activity is to find out the limiting case (maximum break area size) for the Peak Cladding Temperature for LOCAs under fixed boundary conditions.

Downloads

Download data is not yet available.

Published

2022-07-18